Product description

../../_images/7200561935_S92_Construction_00.svg

Dimensions, design and function of BTL PE _ 400 _ _ _ _ E11A _ 01 000S92

1

Position marker

2

Unusable area

3

Measuring length

4

Zero point

5

BTL PE6400… : 50 mm

BTL PE7400… : 42.5 mm

../../_images/7200561935_S01_Construction_00.svg

Dimensions, design and function of BTL PE _ 400 _ _ _ _ E11A _ 01 000S01

1

Position marker

2

Unusable area

3

Measuring length

4

Zero point

5

BTL PE6400… : 50 mm

BTL PE7400… : 42.5 mm

Construction

Electrical connection: The electrical connection is made via M12 or DIN plug connection (see Type code).

Housing: Housing containing the processing electronics.

Position magnet: Defines the position to be measured on the waveguide. Magnets are available in various models and must be ordered separately (see Accessories).

Measuring length: Defines the travel/length range available. Sensors with measuring lengths from 25 mm to 1200 mm are available.

Function

To determine the position of a plant component, a magnet is connected to the component. Together they are moved along a waveguide located inside the BTL.

An internally generated INIT pulse interacts with the magnetic field of the magnet to generate a torsional wave in the waveguide which propagates at ultrasonic velocity. The component of the torsional wave which arrives at the end of the waveguide is absorbed in the damping zone to prevent reflection. The component of the torsional wave which arrives at the beginning of the waveguide is converted by a coil into an electrical signal. The position of the magnet and thus at the same time that of the plant component is determined from the running time of the shaft.

Part label

../../_images/Label_BTLPE6400%E2%80%930500%E2%80%93E11AA010%E2%80%93000S92withUL.jpg

Part label (excerpt, example)

1)

Order code

2)

Type

3)

Serial number

Type code

Example

BTL

PE6400

0500

E11AA010

000S92

Definition

BTL

PEa400

bbbb

E11Ac010

000Sdd

Code

Parameter

Meaning

BTL

Sensor type

Magnetostrictive Linear Position Sensor

P

Profile Version

E

Profile housing, flat 29,9×12,5 mm

a

Installation

0 = without mounting clamps
6 = with mounting clamps (BAM MC-TL-075-PE-1), see Mounting clamp with M5 mounting screws
7 = with mounting clamps (BAM MC-TL-076-PE-1), see Mounting clamp with M4 mounting screws

4

Mechanical zero point

Zero point at 65 mm

bbbb

Measuring length

Metric specification in mm; measuring length (0025…1200)

A

Interface

A = Analog

c

Output type

A = Voltage output 0…10 V, rising
E = Current output 4…20 mA, rising
1 = Voltage output 10…0 V, falling
5 = Current output 20…4 mA, falling

dd

Electrical Connection

92 = 5-pin, M12 plug
01 = 4- Pin, DIN EN 175301-803 Form A